- Terminal Blocks[4]
- Connectors[5]
- Electronic & Instrument Enclosures[5]
- Circuit Breakers[10]
- Other Security & Protection Products[1]
- Other Electrical Equipment[2]
- Relays[10]
- Time Switches[5]
- Inverters & Converters[10]
- Current Meters[4]
- Frequency Meters[1]
- Energy Meters[4]
- Voltage Meters[2]
- Contactors[6]
- Power Distribution Equipment[10]
- Transformers[10]
- Other Electronic Accessories[1]
- Doorbells[1]
- Terminals[10]
- Limit Switches[1]
- Wall Switches[1]
- Electrical Plugs & Sockets[5]
- Other Switches[2]
- Other Measuring & Gauging Tools[7]
- Temperature Instruments[4]
- Switching Power Supply[8]
- Contact Person : Ms. Huang Angel
- Company Name : Yueqing Fengda Trade Co., Ltd.
- Tel : 86-577-62667517
- Fax : 86-577-62667501
- Address : Zhejiang,YUEQING,No.238 Road latery 16,Ecnomic Development Zone,YueQing,WenZhou city ,Zhejiang Province ,China
- Country/Region : China
- Zip : 325600
Single output switching power supply
Feature
·Universal AC input/full range·Protections:Short circuit/Over load/Over voltage·Cooling By free air convection·LED indicator for power on·100% full load burn-in test·All using 105°C long life electrolytic capacitors·Withstand 300VAC surge input for 5 second·High operating temperature up to 70°C ·Withstand 5G ·vibration test ·High efficiency,long life and high reliability·1 year warranty ·Dimension: 159*97*38mm (L*W*H)
SPECIFICATIONS
INPUT
Voltage Range:AC 88~264VAC DC 125~373VDC(Withstand 300VAC surge for 5sec,Without damage)
Frenquency:47-63Hz
AC Current:2.5A/ 115AC 1.5A/230VAC
Efficiency:74%(HSC-100-3.3) ;77%(HSC-100-5);81%(HSC-100-12);82%(HSC-100-15);84%(HSC-100-24);84%(HS-100-48)
Inrush Current:Cold start 40A/230VAC
Leakage Current:< 2 mA/240VAC
OUTPUT
PROTECTION
Over Load:110%-150%
Protection Hiccup mode,recovers automatically after fault condition is removed
Over voltage:3.8-4.45V (HSC-100-3.3) ; 5.75-6.75V (HSC-100-5); 13.8-16.2V (HSC-100-12); 17.25-20.25V (HSC-100-15); 27.6-32.4V (HSC-100-24); 55.2-64.8V (HSC-100-48);
ProtectionVoltage limiting, recovers automatically after fault condition is removed
ENVIRONMENT
Working Temp., Humidity:-25°C~+70°C 20%~90 %RH
Storage Temp., Humidity: -40°C~+85°C 10%~95 %RH
Vibration: 10~500Hz,5G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage:I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
Isolation Resistance:I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
STANDARD
Safety Standard:Design refer to UL60950-1,TUV EN60950-1
EMC Standard:Design refer to EN55022 CLASS B,EN61000-3-2,-3; EN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)
OTHERS
Weight:0.6Kg
Packing: 30pcs/18.5Kg/0.99CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation 3.Line Regulation is measured from low line to high line at rate load. 4.Load Stability is measured from 0% to 100% rated load. 5. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.7. Length of set up time is measured at cold first start, turning on-off the power supply very quickly may lead to increase of the set up time.
Single output switching power supply