- Terminal Blocks[4]
- Connectors[5]
- Electronic & Instrument Enclosures[5]
- Circuit Breakers[10]
- Other Security & Protection Products[1]
- Other Electrical Equipment[2]
- Relays[10]
- Time Switches[5]
- Inverters & Converters[10]
- Current Meters[4]
- Frequency Meters[1]
- Energy Meters[4]
- Voltage Meters[2]
- Contactors[6]
- Power Distribution Equipment[10]
- Transformers[10]
- Other Electronic Accessories[1]
- Doorbells[1]
- Terminals[10]
- Limit Switches[1]
- Wall Switches[1]
- Electrical Plugs & Sockets[5]
- Other Switches[2]
- Other Measuring & Gauging Tools[7]
- Temperature Instruments[4]
- Switching Power Supply[8]
- Contact Person : Ms. Huang Angel
- Company Name : Yueqing Fengda Trade Co., Ltd.
- Tel : 86-577-62667517
- Fax : 86-577-62667501
- Address : Zhejiang,YUEQING,No.238 Road latery 16,Ecnomic Development Zone,YueQing,WenZhou city ,Zhejiang Province ,China
- Country/Region : China
- Zip : 325600
atx switching power supply
Feature
Little volume,high efficiency,long life and high reliability·Universal AC input/full range·Protections: Short circuit/Over load/Over voltage·Cooling By free air convection·LED indicator for power on·100% full load burn-in test·1 year warranty·Dimension: 99*97*36mm(L*W*H )
SPECIFICATIONS
INPUT
Voltage Range:AC 88~264VAC DC 125~370VDC
AC Current:0.8A/ 230 V 1.3A/115V
Efficiency:72%(HSC-50-3.3) ;78%(HSC-50-5);81%(HSC-50-12);83%(HSC-50-15);84%(HSC-50-24);86%(HS-50-48)
Inrush Current:Cold start 33A/230VAC
Leakage Current:< 2 mA/240VAC
OUTPUT
PROTECTION
Over Load:110%-160%
Protection Hiccup mode,recovers automatically after fault condition is removed
Over voltage:3.8-4.45V (HSC-50-3.3) ; 5.75-6.75V (HSC-50-5); 13.8-16.2V (HSC-50-12); 17.25-20.25V (HSC-50-15); 27.6-32.4V (HSC-50-24); 55.2-64.8V (HSC-50-48);
ProtectionVoltage limiting, recovers automatically after fault condition is removed
ENVIRONMENT
Working Temp., Humidity:-25°C~+70°C 20%~90 %RH(Refer to output load derating curve)
Storage Temp., Humidity: -40°C~+85°C 10%~95 %RH
Vibration: 10~500Hz,5G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage:I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
Isolation Resistance:I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
STANDARD
Safety Standard:UL60950-1,TUV EN60950-1 Approved
EMC Standard:Design refer to EN55022 CLASS
OTHERS
Weight:0.41Kg
Packing: 45pcs/19.5Kg/0.9CUFT
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation.